Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage


BAHK  

Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage

146 Seiten, 1. Auflage, 2020
166 Abbildungen

  • Reviews in detail the value of gamma correction 99mTc-HDP pinhole bone scan for the evaluation of trabecular microcallus
  • Compares the technique with radiography, CT, and MRI
  • Includes histological correlation
This excellently illustrated monograph summarizes the updated fresh information on the theoretical, practical, and rapidly extended facets of gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan (99mTc-GCPBS) to MRI, CR, and MDCT.

Basically, 99mTc-GCPBS is able to precisely visualize and quantitate callused trabecular microfracture (CTMF) which is as little as 200 μm in size. The extended gamma correction images can very neatly demonstrate CTMF on MRI, conventional radiography (CR), and multidetector computed tomography (MDCT). Whenever appropriate, histological correlation is provided in conjunction with fine gamma corrected images. In this setting, ACDSee 10 gamma correction MRI and CR have been found to offer a highly useful option that deserves wider clinical interest. In practice, gamma correction MRI, CR, and MDCT can distinctly visualize CTMF so that CTMF can be precisely measured simply using an optic lens. By comparison, the naïve MRI, for example, shows CTMF which measures as big as 2 mm in size.

Furthermore, 99mTc-GCPBS can now differentiate bone marrow edema from hemorrhage using the visuospatial mathematic method, which includes the ImageJ of the NIH.

Table of Contents
  • 99mTc-HDP Pinhole Bone Scanning
  • Gamma Correction
  • Gamma Correction 99mTc-HDP Pinhole Bone Scan of Trabecular Microfracture and Endosteal Rimming in Rat
  • Preoperative Radiograph and Gamma Correction 99mTc-HDP Pinhole Scan of Femoral Neck Fracture in Patients
  • Gamma Correction 99mTc-HDP Pinhole Bone Scan Demonstration of Callused Trabecular Microfracture
  • Gamma Correction 99mTc-HDP Pinhole Bone Scan of Callused Trabecular Microfracture in Surgical Specimen: Histological Validation
  • Mathematic and Magnifying Lens Measurements of 99mTc-HDP Uptake in Callused Trabecular Microfracture
  • Corroborative Analysis of Callused Trabecular Microfracture on 99mTc-HDP Pinhole Bone Scan, Surgical Specimen, GCPBS, and H&E Stain
  • ACDSee-10 Gamma Correction 99mTc-HDP Pinhole Bone Scan of Normal Adult Bone Skeleton Viewed from the Stand Point of Wolff’s Law
  • ACDSee-10 Gamma Correction MRI for Neat Imaging and Magnifying Lens Measurement of Callused Trabecular Microfracture
  • ACDSee-10 Gamma Correction Conventional Radiography for Demonstration and Size Measurement of Callused Trabecular Microfracture
  • ACDSee-10 Gamma Correction Multidetector Computed Tomographic Demonstration and Quantitation of Callused Trabecular Microfracture
  • Morphobiochemical Diagnosis of Callused Trabecular Microfracture Using Gamma Correction 99mTc-HDP Pinhole Bone Scan with Histological Validation
  • Differential Diagnosis of Bone Marrow Edema and Hemorrhage and Callused Trabecular Microfracture with Gamma Correction 99mTc-HDP Pinhole Bone Scan Validation
  • Miscellanea of Gamma Correction Medical Imaging

€ 106,99
   
versandkostenfrei - in acht bis zehn Werktagen lieferbar Anzahl:
Preis: € 106,99